Dell POWEREDGE R515 User Manual

Page 41

Advertising
background image

About Your System

41

Alert! Node
Interleaving
disabled! Memory
configuration
does not support
Node
Interleaving.

The memory configuration

does not support node

interleaving, or the

configuration has changed

(for example, a memory

module has failed) so that

node interleaving cannot be

supported. The system still

runs, but without node

interleaving.

Ensure that the memory

modules are installed in a

configuration that supports

node interleaving.

Check other system

messages for additional

information for possible

causes. For memory

configuration information,

see "General Memory

Module

Installation Guidelines" on

page 105. If the problem

persists,

see "Troubleshooting System

Memory" on page 165.

Alert! Power
required exceeds
PSU wattage.
Check PSU and
system
configuration.
Alert!
Continuing
system boot
accepts the risk
that system may
power down
without warning.

The system configuration

of processor(s),

memory modules,

and expansion cards may

not be supported by the

power supplies.

If any system components

were just upgraded,

return the system to the

previous configuration.

If the system boots without

this warning, then the

replaced component(s) are

not supported with this

power supply. If Energy

Smart power supplies are

installed, replace them with

High Output power supplies

to use the components.

See "Power Supplies" on

page 102.

Alert! System
fatal error
during previous
boot.

An error caused the

system to reboot.

Check other system

messages for additional

information for possible

causes.

Message

Causes

Corrective Actions

book.book Page 41 Tuesday, August 24, 2010 1:47 PM