Dell POWEREDGE R515 User Manual

Page 52

Advertising
background image

52

About Your System

Unsupported
memory
configuration.
DIMM mismatch
across slots
detected:
x,x,...

Invalid memory

configuration.

Memory modules are

mismatched in the

specified slots.

Ensure that the memory

modules are installed in a

valid configuration.

See "General Memory

Module

Installation Guidelines" on

page 105.

Unused memory
detected. DIMM’s
installed in the
following slot
are not available
when in 128-bit
advanced ECC
mode: x,x,x

The memory configuration is

not optimal for Advanced

ECC Memory Mode.

Modules in the specified

slots are unused.

Reconfigure the memory for

Advanced ECC Memory

Mode, or change the

memory mode to Optimized

or Sparing in the BIOS setup

screen. See "System

Memory" on page 104.

Warning: A fatal
error has caused
system reset!
Please check the
system event log!

A fatal system error

occurred and caused the

system to reboot.

Check the SEL for

information that was logged

during the error. See the

applicable troubleshooting

section in "Troubleshooting

Your System" on page 157 for

any faulty components

specified in the SEL.

Warning: Control
Panel is not
installed.

The control panel is not

installed or has a faulty cable

connection.

Install the control panel, or

check the cable connections

between the display module,

the control panel board,

and the system board.

See "Integrated Storage

Controller Card" on

page 119.

Message

Causes

Corrective Actions

book.book Page 52 Tuesday, August 24, 2010 1:47 PM