About Your System
E2018 Programmable
Timer error.
Power cycle
AC.
Programmable interval
timer error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
E2019 Parity error.
Power cycle
AC.
Parity error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
E201A SuperIO
failure.
Power cycle
AC.
SIO failure.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
E201B Keyboard
Controller
error.
Power cycle
AC.
Keyboard
controller failure.
Remove AC power to the
system for 10 seconds and
restart the system.If the
problem persists,
E201C SMI
initialization
failure.
Power cycle
AC.
System management
interrupt (SMI)
initialization failure.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
E201D Shutdown test
failure. Power
cycle AC.
BIOS shutdown test
failure.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
Code
Text
Causes
Corrective Actions
book.book Page 36 Tuesday, August 24, 2010 1:47 PM