Dell POWEREDGE R515 User Manual

Page 34

Advertising
background image

34

About Your System

E1920 iDRAC6 Upgrade

Failed

The iDRAC6 Express

Card is not installed

properly or the card is bad.

Reseat the iDRAC6

Express Card. If the

problem persists, see

"Getting Help" on

page 187.

E1A14 SAS cable A

failure.
Check
connection.

SAS cable A is missing

or bad.

Reseat the cable. If the

problem persists,

replace cable.
If the problem persists,

see "Getting Help" on

page 187.

E1A15 SAS cable B

failure.
Check
connection.

SAS cable B is missing

or bad.

Reseat the cable. If the

problem persists,

replace cable.
If the problem persists,

see "Getting Help" on

page 187.

E1A1D Control panel

USB cable not
detected.
Check cable.

USB cable to the control

panel is missing or bad.

Reseat the cable.

If the problem persists,

replace cable.
If the problem persists,

see "Getting Help" on

page 187.

E2010 Memory not

detected.
Inspect DIMMs.

No memory was detected

in the system.

Install memory or reseat

memory modules.

See "Installing Memory

Modules" on page 108 or

"Troubleshooting System

Memory" on page 165.

E2011 Memory

configuration
failure.
Check DIMMs.

Memory detected,

but is not configurable.

Error detected during

memory configuration.

See "Troubleshooting

System Memory" on

page 165.

Code

Text

Causes

Corrective Actions

book.book Page 34 Tuesday, August 24, 2010 1:47 PM