Dell POWEREDGE R515 User Manual

Page 31

Advertising
background image

About Your System

31

E1420 CPU Bus parity

error. Power
cycle AC.

The system BIOS has

reported a processor bus

parity error.

Remove AC power to

the system for 10 seconds

and restart the system.
If the problem persists,

see "Getting Help" on

page 187.

E1422 CPU # machine

check error.
Power
cycle AC.

The system BIOS has

reported a machine

check error.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 187.

E1610 Power Supply #

(### W)
missing.
Check power
supply.

Specified power supply

was removed or is missing

from the system.

See "Troubleshooting

Power Supplies" on

page 163.

E1614 Power Supply #

(### W) error.
Check power
supply.

Specified power supply

has failed.

See "Troubleshooting

Power Supplies" on

page 163.

E1618 Predictive

failure on
Power Supply #
(### W).
Check PSU.

An over-temperature

condition or power supply

communication error has

caused the predictive

warning of an impending

power supply failure.

See "Troubleshooting

Power Supplies" on

page 163.

E161C Power Supply #

(### W) lost
AC power.
Check PSU
cables.

Specified power supply

is attached to the system,

but it has lost its

AC input.

Check the AC power

source for the specified

power supply. If the

problem persists, see

"Troubleshooting Power

Supplies" on page 163.

Code

Text

Causes

Corrective Actions

book.book Page 31 Tuesday, August 24, 2010 1:47 PM

Advertising