Dell POWEREDGE R515 User Manual

Page 50

Advertising
background image

50

About Your System

Thermal sensor
not detected
on x

A memory module without a

thermal sensor is installed in

the specified memory slot.

Replace the memory

module. See "System

Memory" on page 104.

Time-of-day
clock stopped

Faulty battery or faulty chip. See "Troubleshooting the

System Battery" on page 162.

Time-of-day not
set - please run
SETUP program

Incorrect Time or Date

settings; faulty system

battery.

Check the Time and Date

settings. See "Using the

System Setup Program and

UEFI Boot Manager" on

page 57. If the problem

persists, replace the system

battery. See "System Battery"

on page 133.

Timer chip
counter 2 failed

Faulty system board.

See "Getting Help" on

page 187.

TPM
configuration
operation
honored. System
will now reset.

A TPM configuration

command has been entered.

The system reboots and

executes the command.

Information only.

TPM
configuration
operation is
pending. Press
(I) to Ignore
OR (M) to Modify
to allow this
change and reset
the system.
WARNING:
Modifying could
prevent
security.

This message displays during

system restart after a TPM

configuration command has

been entered. User

interaction is required to

proceed.

Enter I or M to proceed.

TPM failure

A Trusted Platform Module

(TPM) function has failed.

See "Getting Help" on

page 187.

Message

Causes

Corrective Actions

book.book Page 50 Tuesday, August 24, 2010 1:47 PM

Advertising