Dell POWEREDGE R515 User Manual

Page 44

Advertising
background image

44

About Your System

DIMM
configuration on
each CPU should
match.

Invalid memory

configuration on a

dual-processor system.

The memory module

configuration for each

processor must be identical.

Ensure that the memory

modules are installed in a

valid configuration.

See "General Memory

Module

Installation Guidelines" on

page 105.

Embedded NICx and
NICy:
OS NIC=<ENABLED
|DISABLED>
,
Management
Shared NIC=
<ENABLED
|DISABLED>

The operating system NIC

interface is set in BIOS. The

Management Shared NIC

interface is set

in management tools.

Check the system

management software or the

System Setup program for

NIC settings. If a problem is

indicated, see

"Troubleshooting a NIC" on

page 159.

Error 8602 -
Auxiliary Device
Failure. Verify
that mouse and
keyboard are
securely
attached to
correct
connectors.

Mouse or keyboard cable is

loose or improperly

connected.

Reseat the mouse or

keyboard cable.

Defective mouse or keyboard. Ensure that the mouse or

keyboard is operational.

See "Troubleshooting a USB

Device" on page 158.

Gate A20 failure Faulty keyboard controller;

faulty system board.

See "Getting Help" on

page 187.

Invalid
configuration
information -
please run SETUP
program.

An invalid system

configuration caused a

system halt.

Run the System Setup

program and review the

current settings. See "Using

the System Setup Program

and UEFI Boot Manager" on

page 57.

Invalid PCIe card
found in the
Internal_Storage
slot!

The system halted because

an invalid PCIe expansion

card is installed in the

dedicated storage controller

slot.

Remove the PCIe expansion

card and install the

integrated storage controller

in the dedicated slot. See

"RAID Battery (Optional)"

on page 136.

Message

Causes

Corrective Actions

book.book Page 44 Tuesday, August 24, 2010 1:47 PM