Table 3-11. System Board LED Codes

Group, Meaning

LED

1

LED

2

LED

3

LED

4

LED

5

System is healthy, AC power not present, bad 3.3 V AUX, or PDM not connected.

OFF

OFF

OFF

OFF

OFF

1 - Cables and Installed Components

1

Control panel cable not present

BLINK OFF

OFF

OFF

OFF

2

Backplane cable not present

BLINK OFF

OFF

OFF

ON

3

VRM_P1 missing

BLINK OFF

OFF

ON

ON

4

PROC1 missing

BLINK OFF

ON

OFF

OFF

5

PROC2 present but VRM_P2 missing

BLINK OFF

ON

OFF

ON

6

VRM_P1 present but PROC1 missing

BLINK OFF

ON

OFF

OFF

7

VRM_P1 and VRM_P2 vendor mismatch

BLINK OFF

ON

ON

ON

8

PROC1 and PROC2 core voltage (VID) mismatch

BLINK ON

OFF

OFF

OFF

9

PROC 1 and PROC 2 bus frequency mismatch

BLINK ON

OFF

OFF

ON

10 DDR 200 memory in 533 MHz

BLINK ON

OFF

ON

OFF

11 PROC1 heat sink not installed properly. Thermtrip on PROC1

BLINK ON

OFF

ON

ON

12 PROC2 heat sink not installed properly. Thermtrip on PROC2

BLINK ON

ON

OFF

OFF

2 - VRMs and POWERGOOD

1

PD_ON# from the ICH3 not happening

OFF

BLINK OFF

OFF

ON

2

Power supply not turning ON. +12 V bad or missing.

OFF

BLINK OFF

ON

OFF

3

+1.2V is not good.

OFF

BLINK OFF

ON

ON

4

+1.8V is not good.

OFF

BLINK ON

OFF

OFF

5

+1.25V is not good.

OFF

BLINK ON

OFF

ON