Microprocessors, Microprocessor upgrade kit contents, Removing and replacing a microprocessor – Dell PowerVault 770N (Deskside NAS Appliance) User Manual

Page 64

Advertising
background image

3. Remove the cover (see "

Removing the Cover

").

4. Remove the cooling shroud (see "

Removing the Cooling Shroud

").

5. Locate the memory module connectors from which you will remove memory modules (see

Figure 4-26

).

6. Press down and outward on the memory module connector ejectors until the memory module pops out of the connector

(see

Figure 4-27

).

7. Repeat steps 4 through 6 of this procedure to remove any other memory modules.

8. Perform steps 6 through 11 of the procedure in "

Performing a Memory Upgrade

."

Microprocessors

To take advantage of future options in speed and functionality, you can add a second microprocessor or replace either the

primary or secondary microprocessor.

NOTE:

The second microprocessor must be of the same type as the first. If the two microprocessors are different

speeds, both will operate at the speed of the slower microprocessor.

Each microprocessor and its associated cache memory are contained in a PGA package that is installed in a ZIF socket on the

system board. A second ZIF socket accommodates a secondary microprocessor.

NOTE:

In a single microprocessor system, the microprocessor must be installed in the PROC 1 socket.

Microprocessor Upgrade Kit Contents

A microprocessor

A heat sink

Two securing clips

A VRM, if adding a second microprocessor

Removing and Replacing a Microprocessor

CAUTION:

Only trained service technicians are authorized to remove the system cover and access any of

the components inside the system. See your System Information Guide for complete information about

safety precautions, working inside the computer, and protecting against electrostatic discharge.

1. Open the bezel (see "

Removing the Bezel

").

2. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

3. Remove the cover (see "

Removing the Cover

").

4. Remove the cooling shroud (see "

Removing the Cooling Shroud

").

5. Remove the back fan assembly (see "

Removing the Back Fan Assembly

"). If you are installing a second

microprocessor, go to step 9.

6. Remove the microprocessor heat sink:

a. Press down on the heat-sink securing clips to release the clips from the retaining tabs on the ZIF socket (see

Figure 4-28

).

b. Remove the heat-sink securing clips.