Troubleshooting a wet enclosure – Dell PowerEdge C8000 User Manual

Page 213

Advertising
background image

Troubleshooting

213

Troubleshooting a Wet Enclosure

CAUTION:

Many repairs may only be done by a certified service technician. You

should only perform troubleshooting and simple repairs as authorized in your
product documentation, or as directed by the online or telephone service and
support team. Damage due to servicing that is not authorized by Dell is not covered
by your warranty. Read and follow the safety instructions that came with the
product.

1 Turn off the sleds and attached peripherals
2 Disconnect the enclosure from the electrical outlet or the PDU.

CAUTION:

Wait until all of the indicators on the power supplies turn off before

proceeding.

3 Remove all sleds from the enclosure. See "Removing a Sled" on page 143.
4 Open the sled. See "Sled Covers" on page 148.
5 Disassemble components from the sled. See "Installing System

Components" on page 139.
• Hard-drives
• Cooling shroud
• Processors and heat sinks
• Memory modules
• Expansion card/ RAID controller card
• Mezzanine card
• Interposer extender
• Node power distribution board
• MicroSD card reader

6 Remove all server enclosure components. See the PowerEdge C8000

Systems Hardware Owner’s Manual for more information.

7 Let the sled dry thoroughly for at least 24 hours.
8 Reinstall all server enclosure components. See the PowerEdge C8000

Systems Hardware Owner’s Manual for more information.

9 Reinstall all sled components you removed in step 5.

10 Close the sled. See "Sled Covers" on page 148.

Advertising