Sb error – Dell PowerEdge C8000 User Manual

Page 37

Advertising
background image

About Your System

37

SB Error

Message: “Critical Interrupt Sensor, Correctable, MCU Parity Error”

Table 1-6. SB Error

Byte

Field

Value

Description

1

NetFunLun

10h

2

Platform Event Command

02h

3

Generator ID

01h

Generated by BIOS

4

Event Message Format

Version

04h

Event Message Format Revision.

04h for this specification

5

Sensor Type

13h

Critical Interrupt

6

Sensor Number

77h

SB Sensor ID (depend on

platform)

7

Event Direction Event Type

6Fh

Bit 7: 0 = Assert Event
Bit 6: 0 = Event Type Code

8

Event Data1

AXh

07h: Correctable
08h: Uncorrectable

9

Event Data2

XXh

Bit 7:5Reserved Local error bit

number (4 ~ 0)
00000b: HT Periodic CRC Error
00001b: HT Protocol Error
00010b: HT Flow-Control Buffer

Overflow
00011b: HT Response Error
00100b: HT Per-Packet CRC Error
00101b: HT Retry Counter Error
00111b: MCU Parity Error

10

Event Data3

FFh

FFh: Not Present

Advertising