Dell PowerEdge C8000 User Manual

Page 96

Advertising
background image

96

Using the System Setup Program

Serial port number

(COM1 default)

Select a serial port for console redirection.

• COM1: Enables console redirection via COM1.

See token D7h.

• COM2 as SOL: Enables console redirection via

COM2.

Serial Port Address

(3F8h/2F8h default)

Specifies the base I/O port address of the serial port.

• 3F8h/2F8h: Sets the front serial port address as 0x3F8

and internal serial port address as 0x2F8.

• COM2 as SOL: Sets the front serial port address as

0x2F8 and internal serial port address as 0x3F8.

Serial Port Mode

(115200 8,n,1 as default)

Select a baud rate for the serial port. Options are

[115200 8,n,1], [57600 8,n,1], [38400 8,n,1],

[192008,n,1], and [9600 8,n,1].

Flow Control

(None default)

Select a flow control for console redirection. Options

are [None] and [Software].

Redirection After BIOS

POST (Always default)

If set to Always, the console redirection is always active.

When Disabled, console redirection is turned off after

POST.

Terminal Type

(ANSI default)

Select a target terminal type for console redirection.

Options are [ANSI], [VT100], and [VT-UTF8].

VT-UTF8 Combo Key

Support (Enabled default)

Enables or disables the VT-UTF8 Combination Key

support for ANSI/VT100 terminals.

Option

Description