LLDP Commands
217
no lldp notification-interval
•
interval—The smallest interval in seconds at which to send remote data change
notifications. (Range: 5 - 3600 seconds)
Default Configuration
The default value is 5 seconds.
Command Mode
Global Configuration mode
User Guidelines
This command has no user guidelines.
Example
The following example displays how to set the interval value to 10 seconds.
console(config)#lldp notification-interval 10
lldp receive
Use the lldp receive command in Interface Configuration mode to enable the LLDP receive
capability. To disable reception of LLDPDUs, use the no form of this command.
Syntax
lldp receive
no lldp receive
Default Configuration
The default lldp receive mode is disabled.
Command Mode
Interface Configuration (Ethernet) mode
User Guidelines
This command has no user guidelines.
Example
The following example displays how to enable the LLDP receive capability.
console(config-if-1/g3)#lldp receive