Installing an expansion card, D riser 1. see "installing an, Expansion card – Dell PowerVault NX3000 User Manual

Page 117

Advertising
background image

Installing System Components

117

When the optional x16-link riser is installed, slot 4 is not available.

The expansion-card slots are not hot-swappable.

Besides the integrated storage controller, the system supports a maximum
of two PERC or SAS controller expansion cards to manage external
storage.

CAUTION:

To ensure proper cooling no more than two of the four expansion cards

can have a power consumption of greater than 15W (up to 25W maximum each),
not including the integrated storage controller.

Table 3-1 provides a guide for installing expansion cards to ensure proper
cooling and mechanical fit. The expansion cards with the highest priority
should be installed first using the slot priority indicated. All other
expansion cards should be installed in card priority and slot priority order.

Table 3-1.

Expansion-Card Installation Order

Installing an Expansion Card

WARNING:

Only trained service technicians are authorized to remove the system

cover and access any of the components inside the system. Before you begin this
procedure, review the safety instructions that came with the system.

NOTE:

Before installing any expansion cards, see "Expansion Card Installation

Guidelines."

NOTE:

The procedure for installing expansion cards into risers 1 and 2 is the same

except that slots 3 and 4 on riser 2 have card-edge guides for installing 24.13-cm
(9.5-inch)

expansion cards.

Card
Priority

Card Type

Slot Priority

Max
Allowed

Greater
Than 15W?

1

PERC 6/E controller

3,4,1

2

Y

2

10 Gb NIC

3,4,1,2

2

Y

3

All other Dell storage cards

3,4,1

2

Y

4

All other NICs

1,2,3,4

4

1

N

2

5

Non-Dell storage cards

1,2,3,4

4

1

N

2

1

Maximum of 2 of any card whose maximum power exceeds 15W.

2

Refer to the expansion card documentation to ensure that the maximum power does not exceed
15W.

Advertising