Troubleshooting a Wet System

WARNING:

Only trained service technicians are authorized to remove the system

cover and access any of the components inside the system. Before you begin this
procedure, review the safety instructions that came with the system.

1 Turn off the system and attached peripherals, and disconnect the system

from the electrical outlet.

2 Open the system. See "Opening the System."
3 Disassemble components from the system. See "Installing System

Components."

Cooling shroud

Hard drives

SD cards

USB memory key

NIC hardware key

Internal SD Module

Expansion cards and both expansion-card risers

Integrated storage controller

iDRAC6 Enterprise card

Power supplies

Processors and heat sinks

Memory modules

Fan bracket

4 Let the system dry thoroughly for at least 24 hours.
5 Reinstall the processors and heat sinks, memory modules, power supplies,

cooling shroud, and fan bracket.

6 Close the system. See "Closing the System."
7 Reconnect the system to the electrical outlet, and turn on the system.