background image

32

About Your System

E1A14

SAS cable A

failure.

Check

connection.

SAS cable A is missing or
bad.

Reseat the cable. If the
problem persists, replace
cable.

If the problem persists,
see "Getting Help."

E1A15

SAS cable B

failure.

Check

connection.

SAS cable B is missing or
bad.

Reseat the cable. If the
problem persists, replace
cable.

If the problem persists,
see "Getting Help."

E1A1D

Control panel

USB cable not

detected.

Check cable.

USB cable to the control
panel is missing or bad.

Reseat the cable. If the
problem persists, replace
cable.

If the problem persists,
see "Getting Help."

E2010

Memory not

detected.

Inspect

DIMMs.

No memory was detected in
the system.

Install memory or reseat
the memory modules. See
"Installing Memory
Modules" or
"Troubleshooting System
Memory."

E2011

Memory

configuration

failure.

Check DIMMs.

Memory detected, but is
not configurable. Error
detected during memory
configuration.

See "Troubleshooting
System Memory."

E2012

Memory

configured

but unusable.

Check DIMMs.

Memory configured, but is
unusable.

See "Troubleshooting
System Memory."

E2013

BIOS unable

to shadow

memory. Check

DIMMs.

The system BIOS failed to
copy its flash image into
memory.

See "Troubleshooting
System Memory."

Table 1-1.

LCD Status Messages (continued)

Code

Text

Cause

Corrective Actions