Dell PowerVault NX3000 User Manual

Page 38

Advertising
background image

38

About Your System

Alert! iDRAC6 not

responding.

Rebooting.

The iDRAC6 is not
responding to BIOS
communication either
because it is not functioning
properly or has not
completed initialization.
The system will reboot.

Wait for the system to
reboot.

Alert! iDRAC6 not

responding.

Power required

may exceed PSU

wattage.

Alert!

Continuing

system boot

accepts the risk

that system may

power down

without warning.

The iDRAC6 is hung.

The iDRAC6 was remotely
reset while system was
booting

After AC recovery, the
iDRAC6 takes longer than
normal to boot.

Remove AC power to the
system for 10 seconds and
restart the system.

Alert! Node

Interleaving

disabled! Memory

configuration

does not support

Node

Interleaving.

The memory configuration
does not support node
interleaving, or the
configuration has changed
(for example, a memory
module has failed) so that
node interleaving cannot be
supported. The system will
run but without node
interleaving.

Ensure that the memory
modules are installed in a
configuration that supports
node interleaving. Check
other system messages for
additional information for
possible causes. For memory
configuration information,
see "General Memory
Module Installation
Guidelines." If the problem
persists, see
"Troubleshooting System
Memory."

Table 1-2.

System Messages (continued)

Message

Causes

Corrective Actions

Advertising