About Your System

39

Alert! Power

required exceeds

PSU wattage.

Check PSU and

system

configuration.

Alert!

Continuing

system boot

accepts the risk

that system may

power down

without warning.

The system configuration of
processor(s), memory
modules, and expansion
cards may not be supported
by the power supplies.

If any system components
were just upgraded, return
the system to the previous
configuration. If the system
boots without this warning,
then the replaced
component(s) are not
supported with this power
supply. If Energy Smart
power supplies are installed,
replace them with the High
Output power supplies to use
the components. See "Power
Supplies."

Alert! Redundant

memory disabled!

Memory

configuration

does not support

redundant

memory.

Memory Mirroring was
enabled in the system setup
program, but the current
configuration does not
support redundant memory.
A memory module may be
faulty.

Check the memory modules
for failure. See
"Troubleshooting System
Memory." Reset the memory
setting, if appropriate. See
"Using the System Setup
Program and UEFI Boot
Manager."

Alert! System

fatal error

during previous

boot.

An error caused the system
to reboot.

Check other system
messages for additional
information for possible
causes.

BIOS

MANUFACTURING

MODE detected.

MANUFACTURING

MODE will be

cleared before

the next boot.

System reboot

required for

normal

operation.

System is in manufacturing
mode.

Reboot to take the system
out of manufacturing mode.

Table 1-2.

System Messages (continued)

Message

Causes

Corrective Actions