4) The compressor does not revolve or hard to revolve.

The vibration of belt is large.

The belt is sliding.

Sliding when revolving

Sliding when revolving

Sliding caused by the contamina-
tion around the magnetic clutch

Tension adjustment

Repair/replacement

Battery charging

Replacement of magnetic clutch

Replacement or cleaning the
surface of clutch.

Causes

Checking Methods

Action

1. Loosening of belt

2. Internal failure of compressor

3. Relation of magnetic clutch

3-1. Drop of battery voltage

3-2. Layer shot of coil

3-3. Oil invasion to the surface of

clutch

C. TROUBLE SHOOTING BY GAUGE

PRESSURE

569W919A

569W920A

a. Not Cool

1. Lack of refrigerant charging

Status: Not cool

Phenomena:

- The pressure of high /low pressure side is low.

- The bubble in sight glass is seen.

- Discharging temperature does not fall down.

Cause: Refrigerant leakage

Action: Check with gas leakage detector and repair
the leaked part and supplement the proper amount.

CONNECTION OF MANIFOLD GAUGE

: Exhaust the air by loosening the nut.

1. Connect the manifold gauge to the high/low pres-

sure connection section of the compressor.

2. Exhaust the air in the charging hose from the con-

tacting side of manifold gauge.

*

Condition

Ambient temperature: 30 ~ 35°C (86 ~ 95°F)

Revolution of engine: 150 rpm

Blower: HI (Maximum revolution)

Thermo. switch: Colder

*

Reference

1.5 ~ 2.0 kgf/cm

2

21.3 ~ 28.4 psi

1.5 ~ 2.0 kgf/cm

2

21.3 ~ 28.4 psi

Low pressure side

High pressure side

1 kgf/cm

2

14.2 psi

8 ~ 9 kgf/cm

2

113.8 ~ 128.0 psi

Low lack of refriger-

ant charging

High lack of refriger-

ant charging