Cabin system 9-17 – Cub Cadet 8454 User Manual

Page 331

Advertising
background image

CABIN SYSTEM

9-17

D569-W02 May-2003

569W921A

569W922A

When exhausting the refrigerant, ex-
haust it to the low pressure side slowly
and check the pressure graduation
and sight glass to check the amount
of refrigerant.

Pay attention to the contamination of
radiator.

2. Excess of refrigerant charging

Status: Not cool

Phenomena:

- Pressure rising by overcharging of refrigerant

- Lack of cooling of the compressor

Cause:

- Pressure rising by overcharging of refrigerant

- Lack of cooling of the compressor

Action:

- Clean the compressor

- Check and adjust fan belt or compressor motor

- Check the amount of refrigerant

3. Air mixing (lack of vacuum working)

Status: Not cool

Phenomena:

- The pressure of high /low pressure side is high.

- The pipe of low pressure side is not cold.

Cause: Air mixing in the refrigerating cycle. In case
of no vacuum working, the graduation is shown on
the left figure.

Action: When charging the refrigerant by making a
vacuum, check the guide.

In case of operating for a long time in the state of air
mixing, replace the receiver drier.

2.5 ~ 3.5 kgf/cm

2

35.6 ~ 49.8 psi

20 kgf/cm

2

284.5 psi

Low excess of

refrigerant charging

High excess of

refrigerant charging

2.5 ~ 3.5 kgf/cm

2

35.6 ~ 49.8 psi

23 ~ 24 kgf/cm

2

327.1 ~ 341.3 psi

Low air mixing in the

refrigerating cycle

High air mixing in the

refrigerating cycle