Site Information
05855E
39
4.6.1.3 MOD 3
4.6.1.4 MOD 4
Field
Start Column
Width
Description
Transmitter ID
7
10
Factory-assigned serial number, universally
unique
Meter Count
20
6
Reading on meter in respective unit
Utility Type
27
1
W: Water; other meter types have not been
implemented
Meter Connection
29
1
H: Hot; C: Cold; A: All
Exception
32
1
E: notes that an exception has occurred on the
same day
Date of Last Read
34
8
Date when last meter read was recorded
Time of Last Read
43
5
Time when last meter read was recorded
Meter ID
49
12
User-assigned to help identify the meter
location
Exception Code
62
3
I: inactive; B: low battery; T: test mode; R:
reset; P: registered but never checked in