4.6.1.6 Available Reads:

Displays the reads from which you can create an .OUT file. To create an .OUT
file, check an available read, and click the Create button.

4.6.1.7 Choose Format:

Allows you to choose the format in which the .OUT file will be created.

4.6.1.8 Choose Destination:

Allows you to choose the destination to which the .OUT file will be exported.

4.6.1.9 Synchronize Data with the Data Logger

Data synchronized includes meter reads, site configuration, and exceptions.
Newer data always overwrites older data, so be sure you are not overwriting
changes made on the other end of the synchronization. The easiest way to
make sure of this is to perform a synchronization before making any changes,
ensuring that you start with the newest data in your software and data logger.

• If you are performing a synchronization where there are site configuration

updates in either TapWatch 3 or the data logger, TapWatch 3 will
recommend whether to click Publish or Retrieve. In most cases, the
recommended action is the correct one.

• If you are performing a synchronization where there are site configuration

updates in both TapWatch 3 and the data logger, TapWatch 3 will ask you
which updates to keep. Forced Retrieve will keep the updates from the
data logger; Forced Publish will keep the updates from TapWatch 3. In
most cases it is recommended to click Forced Retrieve.

• If you try to synchronize data with a site that is not registered to

TapWatch.com but which has been selected as a TapWatch.com site on
the Settings screen, a window with a list of blank data loggers will display.
Highlight the appropriate data logger and click Publish.

• If you are publishing to a blank data logger, you will be prompted that

TapWatch 3 detects a site configuration change. The recommended
action is to click Publish.

To synchronize data with the data logger:

1.

Navigate to File > Connect > Sync; or, click on the Connect/Sync button.

2.

Synchronization progress will display in the status bar.