1 connecting the unit to sensor amplifiers, Mounting the unit, Mounting the unit on a din rail – KEYENCE DL-RB1A User Manual

Page 12: Connecting the unit to sensor amplifiers

Advertising
background image

10

M

ou

ntin

g an

d Co

nn

ec

tin

g the
D

L-

R

B

1A

2

2-1

Connecting the Unit to Sensor Amplifiers

This section describes how to mount DL-RB1A and connect it to sensor amplifiers.

Mounting the Unit

Mounting the unit on a DIN rail

1

Fit the tab of the lower part of the unit to the DIN
rail. While inserting the unit in the direction of
arrow (1), push the body down in the direction of
arrow (2).

2

To detach the unit, lift the unit in the direction of
arrow (3) while pushing it in the direction of arrow
(1).

When using the mounting bracket (OP-60412), install it as shown in the illustration below.

Connecting the Unit to Sensor Amplifiers

When connecting DL-RB1A to the sensor amplifiers, the connection method varies according to the
mounting type of the sensor amplifiers. Before connecting DL-RB1A, you must install any necessary
expansion units to the main unit of the sensor amplifier.
For information on installing the sensor amplifiers, refer to the user's manual supplied with the sensor amplifiers.

(1)

(2)

(3)

Mounting bracket: OP-60412

Caution

Make sure that the sensor amplifiers are turned off before connecting the
BCD output unit DL-RB1A to them. Connecting the unit while the sensor
amplifiers are turned on may damage the unit.

Advertising