Data that can be output – KEYENCE DL-RB1A User Manual

Page 14

Advertising
background image

12

M

ou

ntin

g an

d Co

nn

ec

tin

g the
D

L-

R

B

1A

2

2-1

Connecting the Unit to Sensor Amplifiers

• When connecting 3 or more models together

When using 2 or more models together, the total connection number for each model must be the
maximum connectable number or less for connecting one model only.
(Example) When IB Series and IG Series are used together, sum of the 2 models must be 6

units or less. In addition, the number of IB Series and IG Series must be 4 or less
respectively.
(Connectable)

IB Series 4 units, IG Series 2 units, Total 6 units

(Not connectable) IB Series 5 units, IG Series 1 units, Total 6 units

*2 As for the large display type, GT2-100 Series, up to 11 units of the sensor head can be connected

to 1 amplifier by adding the expansion board to the main unit.
GT2-100 Series cannot be used with other models.

DL-RB1A cannot be connected to the GT-70 Series.

Data that can be output

*1 When using the calculation function in a display other than reference difference display on the

GT-70A Series and GT2 Series, the P.V. value (criterion value) for the main unit can be output by
selecting ID No. 15, while the R.V. value (raw value) can be output by selecting ID No. 00.
For more information about selecting ID numbers, refer to "I/O Connector" (page 15)

*2 If the measurement mode is set to the "Pin interval judgment mode" or "Pin diameter judgment

mode", the output data is fixed to "-099998". For details on the measurement mode, refer to the
IG Series User's Manual.

* For more information on data, refer to the User's Manual of each sensor amplifier.

Model

Amplifier used

together 1

Amplifier used

together 2

Maximum connectable number

(DL not included)

GT-70A Series

GT2 Series

IL Series

8 units

Other combinations

6 units

Note

Type of amplifier

Calculation

function OFF

Calculation function ON

Calculation

dedicated mode

Other displays

Reference

difference display

High-accuracy digital

contact sensor

GT2 Series

Main unit

P.V. values

(criterion values)

P.V. values (criterion values)

*1

R.V. values (raw values)

P.V. values

(criterion values)

P.V. values

(criterion values)

Expansion

unit

P.V. values

(criterion values)

R.V. values (raw values)

P.V. values

(criterion values)

P.V. values

(criterion values)

General purpose

digital

contact sensor

GT-70A Series

Main unit

P.V. values

(criterion values)

P.V. values (criterion values)

*1

R.V. values (raw values)

R.V. values

(raw values)

-

Expansion

unit

P.V. values

(criterion values)

R.V. values (raw values)

P.V. values

(criterion values)

Multi-Purpose CCD

Laser Micrometer

IG Series

Main unit

P.V. values (criterion values)

*2

-

-

Expansion

unit

CMOS Laser

Application Sensor

IL Series

Main unit

P.V. values (criterion values)

-

-

Expansion

unit

Thrubeam Laser

Detection Sensor

IB Series

Main unit

P.V. values

(criterion values)

-

-

-

Expansion

unit

Static Sensor

SK-1000 Series

Main unit

P.V. values

(criterion values)

-

-

-

Expansion

unit

Advertising