The following special output occurs depending on the sensor amplifier data. For information on

conditions that produce an alarm, refer to "Pin No. 32: Alarm output".

• DL-RB1A does not output decimal points. If there is a decimal point in the sensor amplifier

data, it will be dropped.

[Ex.] When the GT2 Series is connected, the detection data "+12.3456"

is output to the DL-RB1A as "+123456".

• The number of digits sent out of the BCD output cannot be changed. (This does not affect

the number of digits displayed on the sensor amplifier.)

• The GT2 Series sensor amplifier can display up to 7 digits, but DL-RB1A can only output

up to 6 digits.

Pin No. 31: Strobe output

Strobe output is turned on when data can be read from the external device.

When the strobe output is turned off, the BCD output cannot be verified.

Pin No. 32: Alarm output

Alarm output is turned on normally. It is turned off when an alarm occurs.

When an alarm occurs, "+EEEEEE" is output as the BCD data and polarity code.
• The time after the power is turned on but before the first BCD output is confirmed

• When updating the BCD output, if the selected ID number for the sensor amplifier does not exist

• When updating the BCD output, if there is an error with the selected ID number for the sensor

amplifier

• When there is overcurrent error on one of the outputs (Pin Nos. 6 to 32)

• Until the initialization is completed if the main unit (ID: 00) is initialized when it is connected to the

GT2-100N/100P.

* For more information on errors, refer to the User's Manual of each sensor amplifier.

Sensor amplifier

Data

state

Alarm output

Sensor amplifier display

High-precision Digital

Contact Sensor

GT2 Series

-999998

No data

ON

-------

+EEEEEE

Alarm

OFF

Error display

or abnormal

*

+999999

Exceed upper limit

ON

+100.0000 or less,

or FFFF

-999999

Exceed lower limit

ON

-100.0000 or less,

or -FFFF

General Purpose

Digital

Contact Sensor

GT-70A Series

-999998

No data

ON

-------

+EEEEEE

Alarm

OFF

Error display

or abnormal

*

+999999

Exceed upper limit

ON

FFFF

-999999

Exceed lower limit

ON

-FFFF

Multi-Purpose CCD

Laser Micrometer

IG Series

-099998

No data

ON

-------

+EEEEEE

Error

OFF

Error display

or abnormal

*

+099999

Exceed upper limit

ON

99.999 or FFFF

-099999

Exceed lower limit

ON

-99.998 or less,

or -FFFF

CMOS Laser

Application Sensor

IL Series*

-099998

No data

ON

-------

+EEEEEE

Error

OFF

Error display

or abnormal

*

+099999

Exceed upper limit

ON

99.999 or FFFF

-099999

Exceed lower limit

ON

-99.998 or less,

or -FFFF

Thrubeam Laser

Detection Sensor

IB Series

-099998

No data

ON

-------

+EEEEEE

Error

OFF

Error display or

abnormal*

+999999

Exceed upper limit

ON

-99.998 or less, or FFFF

-999999

Exceed lower limit

ON

-999.98 or -FFFF

Static Sensor

SK-1000 Series

-099998

No data

ON

-------

+EEEEEE

Error

OFF

Error display

or abnormal*

+099999

Exceed upper limit

ON

99.999 or FFFF

-099999

Exceed lower limit

ON

-99.998 or less, or -FFFF

* If the source of the alarm output is on the DL-RB1A, the sensor amplifier continues to show a normal display.

When using the GT2-100 Series, “-999998” is output if the data of the ID outside the range of the valid ID setting is read.

Note

Advertising