Factory default positions are shown – KEYENCE DL-RB1A User Manual

Page 9

Advertising
background image

7

1-1

Before Using the Unit

In

tro
du

ct

ion

1

(1) Advanced setting switches

You can use different ON/OFF combinations to configure the output settings.

• Make sure you cycle the power to the unit after modifying

the settings. The modifications are not applied to the unit

until it is powered down and power has been reapplied.

• Place the switch protection sticker supplied with the unit

over the switches after you modify the settings.

Switch No.

Setting item

Combination

1

Output logic

Setting enabled only for BCD output (Pin Nos. 6 to 29) and
BCD polarity code output (Pin No. 30).

* Factory default positions are shown.

Negative logic: The bit for each BCD output will be 1 when the

BCD output (Pin Nos. 6 to 30) is on.

Positive logic: The bit for each BCD output will be 1 when the

BCD output (Pin Nos. 6 to 30) is off.

2

BCD data

output method

Set the method for handling all outputs except for the alarm
output (Pin Nos. 6 to 31).

* Factory default positions are shown.

Do not use combinations other than those shown above for
switch numbers 2 and 3.

3

4

BCD output update

cycle time in the

TIMER mode

* Factory default positions are shown.

5

6

ON

1

ON

1

Negative logic* Positive logic

ON

2 3

ON

2 3

ON

2 3

OUT mode*

OR mode TIMER mode

Note

ON

ON

ON

ON

4 5 6

ON

ON

ON

ON

4 5 6

4 5 6

4 5 6

4 5 6

4 5 6

4 5 6

4 5 6

1ms

*

2ms

4ms

8ms

16ms

32ms

64ms

128ms

Note

Switch protection sticker