1 specifications, Performance specifications, Specifications – KEYENCE DL-RB1A User Manual

Page 34

Advertising
background image

32

A

ppe

nd

ix

4

4-1

Specifications

Performance specifications

The following table shows the performance specifications for DL-RB1A.

* The number of connectable sensor amplifiers varies depending on the model to be connected.

For details, refer to "Available sensor amplifiers" (page 11).

Item

Specifications

Model

DL-RB1A

Power supply voltage

20 to 30 VDC, including 10% ripple (P-P). Class2
(supplied from the connected sensor amplifier)

Current consumption

27 mA max.

Number of connected sensor
amplifiers

Varies depending on the model

*

Indicators

Alarm indicator (red), power indicator (green)

I/O terminal

34-pin connector (MIL standard)

Control outputs

BCD output: 4 (1 digit) x 6 digits, code output, strobe output, alarm output
NPN open collector: 40 V, 20 mA max., residual voltage 1 V max.
Positive/negative logic: Switchable

Control inputs

ID selection input: 4 inputs, data request input
Non-voltage input (with contacts, without contacts), input time 2 ms min., short-circuit
current 1 mA

Environmenta
l resistance

Surrounding air
temperature

-10

C to +55

C (No freezing)

Relative
humidity

35 to 85% RH (No condensation)

Vibration

10 to 55 Hz, compound amplitude 1.5 mm, 2 hours for each of XYZ axes

Material

Main unit housing: polycarbonate

Weight

Approx. 46g

Accessories

Instruction manual, 2 end units, expansion connector cover, switch protection seal

Advertising