Communication Unit Data Update Time

After the sensor is detected, the DL-RB1A can output data after the sensor amplifier response time

(T1)

*

and DL-RB1A data processing time (T2) have passed.

DRQ input from an external device starts after T1 and T2 have passed.
* For more information on sensor amplifier response time, refer to the manual supplied with the

sensor amplifiers.

Time chart

T1: Sensor amplifier response time

T2: DL-RB1A data processing time

DL-RB1A data processing time (T2)

The processing time for T2 varies depending on the sensor amplifier calculation function and the

number of sensor amplifiers that are connected.

* ID No. 15 outputs the P.V. value for the main unit when using a calculation function other than the

reference difference display on the GT-70A Series.

During this time, ID No. 00 outputs the P.V. value for the main unit.

ID No. 15 is not used when the calculation function is not used or when reference difference display is used.

When using reference difference display, the processing time for ID Nos. 01 to14 becomes the

same as the processing time for ID No. 15.

For information on the calculation function, refer to the manual supplied with the sensor amplifiers.

Sensor amplifier

DL-RB1A

Detected data update

DL-RB1A data processing complete

Detection

T1

T2

1. Data processing time for the number of sensor

amplifiers connected without using the calculation

function (ID No.15)

When using the GT2-100N/100P, add 50 ms to the above value.

Number of connected

sensor amplifiers

Data processing time (T2)

GT-70A Series/

GT2 Series

IG Series/

IB Series

IL Series/

SK-1000 Series

1

7 ms

5 ms

9 ms

2

9 ms

10 ms

11 ms

3

13 ms

12 ms

14 ms

4

15 ms

16 ms

18 ms

5

19 ms

-

20 ms

6

21 ms

-

24 ms

7

25 ms

-

27 ms

8

27 ms

-

31 ms

9

31 ms

-

-

10

33 ms

-

-

11

37 ms

-

-

12

39 ms

-

-

13

43 ms

-

-

14

45 ms

-

-

15

49 ms

-

-

2. Data processing time for the number of

sensor amplifiers connected while using

the calculation function (ID No.15)

When using the GT2-100N/100P, add 75 ms to the
above value.

Number of connected

sensor amplifiers

T2

1

10.5 ms

2

13.5 ms

3

19.5 ms

4

22.5 ms

5

28.5 ms

6

31.5 ms

7

37.5 ms

8

40.5 ms

9

46.5 ms

10

49.5 ms

11

55.5 ms

12

58.5 ms

13

64.5 ms

14

67.5 ms

15

73.5 ms

Advertising