Connecting the DL-RB1A to External Devices

Precautions when wiring (OP-23139 and OP-42224)

Carefully follow the precautions below when performing wiring.
• Use a single shielded cable.
• Use the following type of compliant cable:

Cable size:

AWG24 to 22 (stranded)

Cross-section:

0.2 to 0.3 mm

2

Cable sheath diameter:

1.5 to 1.1

• Cut the end of the cable straight across.

• After performing the wiring, check that the cable is securely held in the clamp and that it is inserted

firmly.

• Cut the cable clearly so that no loose threads remain. (The sheath does not need to be removed.)
• Use the thin cable contacts OP-30594 (200 pieces included) for AWG28 to 26.

(Use this together with OP-23139 or OP-42224.)

Cable size:

AWG28 to 26

Cross-section:

0.08 to 0.14 mm

2

Cable sheath diameter:

1.3 to 1.1