T#p)g, Vk06, Ib-e a ppendix – KEYENCE IB Series User Manual

Page 113: Error indication error contents remedy, Reference

Advertising
background image

A-5

IB-E

A

ppendix

Receiver error

The receiver is not connected
to the sensor amplifier.

Correctly connect the receiver.

"Connecting the Sensor Head" (page 2-9)

The sensor head cable
connector is not connected
correctly.

Connect the connector again.

"Attaching the sensor head cable connector
(OP-87060)" (page 2-11)

The receiver is broken.

Replace the receiver.

The sensor head cable for the
receiver is broken.

Replace the sensor head cable.

Transmitter laser
error

The laser in the transmitter is
broken.

Replace the transmitter.

Transmitter error

The transmitter is not
connected to the sensor
amplifier.

Correctly connect the transmitter.

"Connecting the Sensor Head" (page 2-9)

The sensor head cable
connector is not connected
correctly.

Connect the connector again.

"Attaching the sensor head cable connector
(OP-87060)" (page 2-11)

The transmitter is broken.

Replace the transmitter.

The sensor head cable for the
transmitter is broken.

Replace the sensor head cable.

Model mismatch error

The transmitter and receiver
model (measurement range)
do not match.

Use a transmitter and receiver from the same
model (measurement range).

Transmitter
internal error

The transmitter is broken.

Replace the transmitter.

Overcurrent error

An overcurrent exceeding the
specifications passed to the
judgment output or check
output.

• Correct the wiring.

"Output Circuit" (page 5-4)

• Check the load and reduce the current to

within the specified range.

• Check that the output wire is not touching

another wire or frame.

EEPROM error

Read/write of the non-volatile
memory (EEPROM) save
data failed.

Turn the power on again.
Perform initial reset.

"3-5 Initial Reset (Initialize)" (page 3-12)

The number of writes to the
non-volatile memory
(EEPROM) exceeded
1,000,000 times.

To save the setting values when the power is
turned off, replace the amplifier unit.

If the adjust function or the zero shift function is used frequently, do
not save settings in the non-volatile memory (EEPROM).

"12. Save Zero-Shift State" (page 4-36)
"13. Save Adjust State" (page 4-36)

Error indication

Error contents

Remedy

T

LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

'T*

GO

HOLD

CALC

CHECK

.#5'4

LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

'T*

GO

HOLD

CALC

CHECK

V

LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

'T*

GO

HOLD

CALC

CHECK

T#P)G

LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

'T*

GO

HOLD

CALC

CHECK

VK06

LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

'T*

GO

HOLD

CALC

CHECK

LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

'T%

GO

HOLD

CALC

CHECK

LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

'T'

GO

HOLD

CALC

CHECK

Reference

Advertising