6 setting the tolerance setting value, 6 setting the tolerance setting value -13, Setting the tolerance setting value -13 – KEYENCE IB Series User Manual

Page 41: Setting the tolerance setting value

Advertising
background image

3-13

3

B

a

sic O

perat

io

ns

IB-E

3-6

Setting the Tolerance Setting Value

The tolerance setting value consists of the upper limit value (HIGH setting value) and the
lower limit value (LOW setting value). By setting these values, judgments are made in three
levels: when the judgment value (P.V.) goes beyond the upper limit (HIGH judgment), when
the judgment goes beyond the lower limit (LOW judgment) and when the judgment is within
the acceptable range (GO judgment). Then, the judgment indicator and judgment output
are turned ON/OFF.

*1

When the output mode of judgment output is Normally Open (default value) ON/OFF
is reversed for Normal Close.

"4. Output Mode" (page 4-13)

*2

The judgment indicator ON/OFF condition can be changed.

"20. Judgment Indicator Color" (page 4-41)

*3

"Error Displays and Corrective Actions" (page A-4)

The tolerance setting value can be set either manually or automatically.

Judgment

Judgment output

*1

Judgment output

*2

HIGH

GO

LOW

HI

GO

LO

HIGH

ON

OFF

OFF

Lights in red

OFF

OFF

GO

OFF

ON

OFF

OFF

Lights in green

OFF

LOW

OFF

OFF

ON

OFF

OFF

Lights in red

Error

*3

ON

OFF

ON

Lights in red

OFF

Lights in red

DIN rail mount type (IB-1000/IB-1050)

Panel mount type (IB-1500/IB-1550)

Item

Setting Method

Manual setting

Directly enter the tolerance setting value (HIGH setting
value, LOW setting value).

Automatic
setting

Tolerance tuning

Detect the master workpiece and set the tolerance.

2-point tuning

Detect the good target and defective target and set the
tolerance.

Point

When setting the tolerance setting value manually using the 2-point
tuning, make sure to set HIGH setting value to be larger than LOW
setting value.

Reference

When setting HIGH setting value to be smaller than LOW setting value, the
judgment output is as follows.
• GO judgment output is not output regardless of the judgment value (P.V.).

(When setting HIGH setting value = LOW setting value = judgment value
(P.V.), and the hysteresis to 0.000, GO judgment output is turned on.)

• When the judgment value (P.V.) goes beyond the HIGH setting value and

falls below the LOW setting value, the HIGH judgment output and LOW
judgment output are output at the same time.

Judgment indicator

Advertising