Bank Function (Registering
Multiple Tolerance Setting Values)

Using the bank function, you can register up to four patterns of specified tolerance settings.
By using the bank function, each setting item registered beforehand can be switched easily.

*1

The shifted amount when the internal measurement value (R.V.) is shifted using the
zero shift function is saved in each bank.
Example:

Suppose the zero shift function is used with bank 0, then the unit is
switched to bank 1, and while in bank 1, the zero shift is used again. If the
unit is switched back to bank 0, the zero shift associated with bank 0 is
recalled.

Settings Registered with the Bank

Settings

Reference page

HIGH setting value

"3-6 Setting the Tolerance Setting Value" (page 3-
13)

LOW setting value

Shift target value

*1

"3-7 Zero Shift Function (Shifting the Internal
Measurement Value (R.V.))" (page 3-18)