External input, External input -29, External input setting screen – KEYENCE IB Series User Manual

Page 81: 5jk(v, Tgugv, 6k/p), 2 basic settings and advanced settings, Ib-e, Bank switching method, Power/input-output cable" (page 2-7)

Advertising
background image

4-2 Basic Settings and Advanced Settings

4-29

IB-E

4

Set
ting V

a

rious

F

unct

ions

You can select functions to be assigned to four external inputs (External input 1 to 4).

" Power/Input-output cable" (page 2-7)

External input setting screen

When the user setting is set, each function of the external input 1 to 4 can be set.
Functions that can be set differ for each external input. (When the default is set, these four
screens are skipped.)

Press the  /  button on each setting screen to specify functions.

10. External Input

External Input

Description

Default value

Default setting

Functions for the external inputs remain the same as
the factory default setting.
External input 1: Zero shift input
External input 2: Reset input
External input 3: Timing input
External input 4: Not used

User setting

Functions for the external inputs are changed from
the factory default setting.

External input 1 (Pink wire)

External input 2 (Yellow wire)

Setting

value

Description

Default

value

Setting

value

Description

Default

value

shift

Zero shift input

reset

Reset input

bnK-a

Bank A input

bnK-a

Bank A input

bnK-b

Bank B input

bnK-b

Bank B input

L-stp

Laser emission stop input

L-stp

Laser emission stop input

off

Not use

off

Not use

External input 3 (Pink/Purple wire)

External input 4 (Purple wire)

Setting

value

Description

Default

value

Setting

value

Description

Default

value

tiMnG

Timing Input

off

Not use

bnK-a

Bank A input

AdJ

Adjust input

bnK-b

Bank B input

bnK-a

Bank A input

L-STP

Laser emission stop input

bnK-b

Bank B input

off

Not use

L-stp

Laser emission stop input

Reference

When the same function is selected for multiple external inputs, if any are
ON, ON (OR operation) works.

75T

LASER

BANK

0

1

2

3

HI

GO

LO

R.V. ANALOG

HI SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

 KP

HOLD CALC CHECK

5JK(V

LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

KP

GO

HOLD

CALC

CHECK

TGUGV

LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

KP

GO

HOLD

CALC

CHECK

6K/P)

LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

KP

GO

HOLD

CALC

CHECK

Q((

LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

KP

GO

HOLD

CALC

CHECK

DVP

LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

DP-

GO

HOLD

CALC

CHECK

10. External input

External input1

setting screen

External input2

setting screen

[MODE]
or 

[MODE]
or 

[MODE]
or 

External input3

setting screen

External input4

setting screen

11. Bank switching method

[MODE]
or 

[MODE]
or 

Advertising