Adjust input

The light deterioration is compensated for when adjust input is turned ON.

Timing chart

*1

All judgment outputs turn off during the adjustment process. The analog voltage
output is fixed to 5.5 V and the analog current output is fixed to 3.0 mA.

*2

The sampling cycle is 80 us when the auto adjust function is disabled, and 160 us
when it is enabled. The adjustment process time while using the high-pass filter is
max. 50 ms.

Minimum input time

ON time: 2 ms
OFF time: 2 ms

Reference

• If the difference between the received light and the reference light

exceeds the setting range for “14. Adjust level”, an adjust error 1 or 2 will
appear on the main screen and the adjust input will be disabled.

" Error Displays and Corrective Actions" (page A-4)
" 14. Adjust Level" (page 4-37)

• If the " 16. Check Output Function" (page 4-38) is set, the check output

will be turned ON when the adjust input is turned ON below the setting
range.

" 16. Check Output Function" (page 4-38)

Max. 6 ms

Min. 2 ms

Min. 2 ms

Max. 60 ms + (averaging x sampling rate

*1

)

During the adjustment process

*1

Internal measurement
value (R.V.)

ON

OFF

Timing input

[- - - - - ]