Inter-character delay, Inter-character delay -10 – KEYENCE BL-N90 Series User Manual
Page 50
3-3 Sending the Reading Data
3-10
3
D
e
scr
ipt
ions of
K
e
y Funct
ions
3 Read data
These digits contain the read barcode data.
4 Terminator
A character can be added to indicate the end of data.
•
This parameter can be set to [CR], [CR][LF], [TAB], or [ETX].
Inter-character Delay
The time between each character can be set to three levels for the data sent from the BL-N90
series to the computer (
If the processing speed on the computer is slow, set a longer value for the inter-character
delay. If the delay is not set long enough, the computer processing speed may fall behind
and digits may be dropped from the data. Adjust the inter-character delay so that data is
received correctly from the reader.
EAN/UPC
EAN/UPC 13 digits
]E0
EAN/UPC 8 digits
]E4
UPC-A 13 digit format
]E0
UPC-A 12 digit format
UPC-E
]X0
CODE128
Not GS1-128
]C0
Is GS1-128
]C1
Second digit of data is FNC1
]C2
CODE93
–
]G0
RSS
–
]e0
Code type
Data specifications
Symbol
identifier