4 nx-50rs connections and wiring, Nx-50rs connections and wiring -16, Nx-50rs connections and wiring – KEYENCE N-410 User Manual
Page 38: Caution
Advertising

2-16
Inst
allatio
2
2-4
NX-50RS Connections and Wiring
The wiring for the NX-50RS is as follows.
Electrical wiring
Power terminal
If using a crimp contact, use a device of the following dimensions.
Electrical wiring
Connect a 24 V DC power source to the power terminal, as shown in the figure.
•
Use a class 2 output power source for 24 V power.
•
Use a D type ground pin (ground resistance no more than 100 ).
Terminal
Dimensions
Round terminal
a:8.0 mm Max
Y terminal
a:6.0mm Max
Item
Contents
Wire size
AWG14-20
Clamping torque
0.51 N
·
m (4.5 lbf
·
in)
Wire material
Copper
Wire type
Strand wire
Electrical
temperature rating
+60
°
C
Power supply
24 V DC ±10%
24 V DC 0 V
Twist
Protective
grounding
Caution
Advertising