Caution, Electrical wiring, Wiring the trigger input – KEYENCE N-410 User Manual
Page 44

2-22
Inst
allatio
2
2-5
N-48 Connections and Wiring
Electrical wiring
Connect a 24 V DC power source to the "IN" side, as shown in the figure.
If 24 V DC power is connected to the "IN" side, the "OUT" side can be used for 24 V DC output.
•
Do not connect to any power voltage other than 24 V DC. Doing so may
damage the device.
•
Connecting an RS-485 terminal to the wrong power supply may cause
damage to the N-48 unit.
•
Do not connect the in and out sides to different types of power sources. A
potential difference between the two power sources could result in
malfunction.
Wiring the trigger input
The trigger input is used to cause a BL/SR/RF Series device to begin reading.
When using the device in multi-head mode, use the trigger input from the N-410 instead of the N-
48.
24V DC OUT
24V DC IN
24V DC
Caution
15 to 26 V DC
TIM COM OK
Circuit diagram
Inter
nal circuit
TIM
COM