Air shutter locking nut location, Initial start-up – AERCO KC1000 Boiler July 2011 User Manual

Page 36

Advertising
background image

INITIAL START-UP

4-4

NOTE:

In the following step, adjust the valve position to

13% for natural gas, or 16% for propane.

19. When the oxygen level is within the

specified range at 30%, change the valve

position to 13% for natural gas (or 16% for

propane).

20. The oxygen levels at the 13% valve position

(or 16% for propane) should be as shown in

Table 2. No adjustment should be

necessary. Contact the factory if the oxygen

or carbon monoxide levels are not within the

specified range.

Table 2

Combustion Oxygen Levels for a 13%

(Natural Gas) or 16% (Propane) Valve

Position

Inlet Air

Temp

Oxygen

(+0.2/-1.0)

Carbon

Monoxide

-20°F

<12 %

<50 ppm

0°F

<12 %

<50 ppm

10°F

<12 %

<50 ppm

30°F

<12 %

<50 ppm

50°F

<11 %

<50 ppm

60°F

<11 %

<50 ppm

70°F

<11 %

<50 ppm

80°F

<11 %

<50 ppm

90°F

<10 %

<50 ppm

100°F

<10 %

<50 ppm

21. Change the valve position to 100%. After the

combustion analyzer has settled, compare

the measured oxygen level with the levels in

Table 3.

Table 3

Combustion Oxygen Levels for a 100%

Valve Position

Inlet Air

Temp

Oxygen

(+0.2/-1.0)

Carbon

Monoxide

-20°F

6.5 %

<150 ppm

0°F

6.3 %

<150 ppm

10°F

6.2 %

<150 ppm

30°F

5.8 %

<150 ppm

50°F

5.4 %

<150 ppm

60°F

5.2 %

<150 ppm

70°F

5.0 %

<150 ppm

80°F

4.8 %

<150 ppm

90°F

4.6 %

<150 ppm

100°F

4.4 %

<150 ppm

22. If the measured oxygen reading is below the

oxygen range in Table 3, loosen the two

bolts that secure the inlet air shutter to the

unit using a 7/16” wrench (see Fig. 4.4).

Open the shutter 1/4” to 1/2” to increase the

oxygen level, then tighten the nuts.

23. Wait for the analyzer to settle then compare

the new oxygen reading to Table 3. Repeat

the inlet air shutter adjustment until the

oxygen is within the specified range. Firmly

tighten the inlet air shutter locking nuts when

finished.

24. If the measured oxygen reading is above the

oxygen range in Table 3, loosen the two

7/16" locking nuts securing the inlet air

shutter.

REMINDER:

At 30% valve position, adjust only the differential

pressure regulator. At 100% valve position,

adjust only the inlet air shutter.

BLOWER

OUTLET

BLOWER

INLET

SCREEN

SHUTTER

SHUTTER

LOCKING

NUTS

Figure 4.4

Air Shutter Locking Nut Location

25. Close the air shutter 1/4” to 1/2” to decrease

the oxygen level and tighten the two nuts.

26. Allow the analyzer to settle then compare

the new oxygen reading to Table 3.

27. Repeat the adjustment until the oxygen is

within the specified range. Firmly tighten the

inlet air shutter locking nuts when finished.