5user interface, 1 foreword, 2 switching the device on/off – EVCO EVXV815P7 Installer manual User Manual

Page 17: 3 the display, 4 cabinet temperature display

Advertising
background image

EVCO S.p.A.

EVXV 800 range | Installer manual ver. 1.2 | Code 144XV800E124

page 17 of 66

5

USER INTERFACE

5.1

Foreword

The following operating status’ exist:

-

the “off” status (the device is not powered)

-

the “stand-by” status (the device is powered and is off)

-

the “on” status (the device is powered, is on and is in stand-by for the start-up of an operating cycle)

-

the “run” status (the device is powered, is on and an operating cycle is in progress).

Hereon, the term "device switch-on" means the passage from the "stand-by" status to the "on" status. The term

"switch-off" means passage from the "on" status to the "stand-by" status.

If a power cut occurs during the "stand-by" status or during the "on" status, the device will re-propose the same

status when the power supply is restored.

If a power cut occurs during the "run" status, the device will operate as follows when the power supply is restored:

-

if a temperature-controlled blast chilling or deep freezing operation was in progress, these will be started again

from the beginning

-

if a time-controlled blast chilling or deep freezing operation was in progress:

-

the EVXV802 and EVXV805 models will be re-started from the time the power cut occurs with a

maximum error of 10 minutes

-

the EVXV812 and EVXV815 models will be re-started from the time the power cut occurs

-

if storage was in progress, this will be re-proposed.

5.2

Switching the device on/off

Operate as follows:

1.

Make sure that the keyboard is not locked and that no procedure is in progress.

2.

Hold the START/STOP key down for 1 s: the

LED will switch on/off.

5.3

The display

The display is off during the "off" status and during the "stand-by" status.

The display shows the cabinet temperature during the "on" status.

The device will operate as follows during the "run" status:

-

if a temperature-controlled blast chilling or deep freezing operation is in progress, the display will show the

temperature detected by the needle probe

-

if a time-controlled blast chilling or deep freezing operation is in progress, the display will show the residual

time of the duration of the same

-

if storage is in progress, the display will show the cabinet temperature.

5.4

Cabinet temperature display

Operate as follows:

1.

Make sure that the keyboard is not locked and that no procedure is in progress.

2.

Hold the DOWN key for 1 s: the display will show the first label available.

3.

Press and release the UP or DOWN key to select “Pb1”.

4.

Press and release the BLAST CHILLING key: the display will show the cabinet temperature.