3 dimensions, 4 uploading the configuration parameters, 5 downloading the configuration parameters – EVCO EVXV815P7 Installer manual User Manual

Page 55

Advertising
background image

EVCO S.p.A.

EVXV 800 range | Installer manual ver. 1.2 | Code 144XV800E124

page 55 of 66

13.1.3

Dimensions

The following drawing illustrates the EVKEY dimensions; these are expressed in mm (in).

13.1.4

Uploading the configuration parameters

Operate as follows:

1.

Cut the device power supply off.

2.

Insert the EVKEY Micromatch connector into the device communication port.

3.

Connect the device power supply. The display will show “Cln” and the EVKEY signal LED will emit a green light.

4.

Hold the BLAST CHILLING key down for 4 s: the display will show flashing “St

5.

Hold the BLAST CHILLING key down for 4 s: download will start, the display will show “St” permanently and the

EVKEY signalling LED will emit a red light.

The download operation requires several seconds. If the operation is not completed successfully within this time

period, i.e. if the EVKEY signalling LED does not stop emitting red light in order to emit green light, the

operation must be repeated.

6.

When downloading has been concluded, the display restores normal viewing and the EVKEY signalling LED

emits green light again.

7.

Disconnect the EVKEY Micromatch connector into the device communication port.

Operate as follows to abandon the procedure:

8.

Do not operate for 60 s.

9.

Disconnect the EVKEY Micromatch connector in the device communication port.

For further information, consult the documentation relative to EVKEY.

13.1.5

Downloading the configuration parameters

Operate as follows:

1.

Make sure that the configuration parameters firmware contained in EVKEY coincide with that of the

device.

2.

Cut the device power supply off.

3.

Insert the EVKEY Micromatch connector into the device communication port.

4.

Connect the device power supply. The display will show “Cln” and the EVKEY signal LED will emit a green light.

5.

Hold the EVKEY programming key down for 1 s: upload will start and the EVKEY signalling LED will emit a red

light.

The upload operation requires several seconds. If the operation is not completed successfully within this time

period, i.e. if the EVKEY signalling LED does not stop emitting red light in order to emit a green light again, the

operation must be repeated.

6.

The display will show “PrG” on conclusion of the upload and the EVKEY signalling LED will emit a green light

again.