EVCO EVXV815P7 Installer manual User Manual

Page 34

Advertising
background image

EVCO S.p.A.

EVXV 800 range | Installer manual ver. 1.2 | Code 144XV800E124

page 34 of 66

Par.

Min.

Max.

Unit

EVXV802

EVXV812

EVXV805

EVXV815

Analogue inputs

CA1

-25.0

25.0

°C/°F (1)

0.0

0.0

cabinet probe offset

CA2

-25.0

25.0

°C/°F (1)

0.0

0.0

needle probe offset

CA3

-25.0

25.0

°C/°F (1)

0.0

0.0

evaporator probe offset

CA4

-25.0

25.0

°C/°F (1)

0.0

0.0

condenser probe offset

P0

0

1

- - - -

0

0

probe type

0 = PTC

1 = NTC

P1

0

1

- - - -

1

1

°C decimal point

1 = yes

P2

0

1

- - - -

0

0

temperature unit of measurement (2)

0 = °C

1 = °F

P3

0

1

- - - -

1

1

enabling the needle probe

1 = yes

P4

0

1

- - - -

1

1

enabling the evaporator probe

1 = yes

P5

0

1

- - - -

1

1

fourth input function

0 = high pressure input (digital input)

1 = condenser probe (analogue input)

P8

0

250

ds

5

5

delay

displaying

temperature

variation

detected by the probes

Par.

Min.

Max.

Unit

EVXV802

EVXV812

EVXV805

EVXV815

Main regulator

r0

0.1

15.0

°C/°F (1)

2.0

2.0

parameters differential r7, r8, r9, r10, r11

and r12

r1

1

500

min

90

90

duration of time-controlled blast chilling

r2

1

500

min

240

240

duration of time-controlled deep freezing

Advertising
This manual is related to the following products: