EVXV 800 range | Installer manual ver. 1.2 | Code 144XV800E124

page 33 of 66

9.

Press and release the UP or DOWN key within 15 s to modify the parameter value:

10.

Press and release the BLAST CHILLING key or do not operate for 15 s: the display will show the parameter label

again.

Operate as follows to exit the procedure:

11.

Hold the UP and DOWN key for 4 s or do not operate for 60 s. The display will show the magnitude indicated in

paragraph 5.3 "The display".

Cut the device power supply off after setting the configuration parameters.

9.3

Restoring the factory settings

Operate as follows:

1.

Make sure no procedures are in progress

2.

Hold the UP and DOWN key for 4 s: the display will show “PA”.

3.

Press and release the BLAST CHILLING key: the display will show “0

4.

Press and release the UP or DOWN key within 15 s to set “149”.

5.

Press and release the BLAST CHILLING key or do not operate for 15 s: the display will show “PA” again.

6.

Hold the UP and DOWN key for 4 s: the display will show “dEF”.

7.

Press and release the BLAST CHILLING key: the display will show “0

8.

Press and release the UP or DOWN key within 15 s to set “1”.

9.

Press and release the BLAST CHILLING key or do not operate for 15 s: the display will show “dEF” flashing for 4

s, after which the device will automatically exit the procedure and the display will show the magnitude indicated

in paragraph 5.3 “The display”.

10.

Cut the device power supply off.

Operate as follows to abandon the procedure:

11.

Hold the UP and DOWN key for 4 s before point 8: The display will show the magnitude indicated in paragraph

5.3 "The display".

Ensure that the factory settings are appropriate; see paragraph 8.4 "List of configuration parameters".

9.4

List of configuration parameters

The following table illustrates the meaning of the configuration parameters.

The management of some inputs and outputs is subject to the value set with some parameters, as follows:

-

management of the needle probe is only available if the parameter P3 is set at 1

-

management of the evaporator probe is only available if the parameter P4 is set at 1

-

management of the condenser probe is only available if the parameter P5 is set at 1

-

management of the high pressure input is only available if the parameter P5 is set at 0

-

in the EVXV802 and EVXV812 models:

-

defrosting management is only available if the parameter u0 is set at 0

-

management of the evaporator fan is only available if the parameter u0 is set at 1

-

in the EVXV805 and EVXV815 models:

-

management of the door resistances is only available if the parameter u1 is set at 0

-

management of the condenser fan is only available if the parameter u1 is set at 1

-

management of the cabinet light is only available if the parameter u11 is set at 0

-

management of needle probe heating is only available if the parameter u11 is set at 1

-

management of the UV light is only available if the parameter u11 is set at 2.