9

CONFIGURATION

9.1

Setting the real date and time (in EVXV812 and

EVXV815 models only)

Operate as follows:

1.

Make sure that the keyboard is not locked and that no procedure is in progress.

2.

Hold the DOWN key for 1 s: the display will show the first label available.

3.

Press and release the UP or DOWN key to select “rtc”.

Operate as follows to set the year:

4.

Press and release the BLAST CHILLING key: the display will show “yy” followed by the last two numbers of the

year and the

LED will flash.

5.

Press and release the UP or DOWN key within 15 s to modify the value:

Operate as follows to set the month:

6.

Press and release the BLAST CHILLING key when setting the year: the display will show “nn” followed by the

two numbers of the month.

7.

Press and release the UP or DOWN key within 15 s to modify the value:

Operate as follows to set the day of the month:

8.

Press and release the BLAST CHILLING key when setting the month: the display will show “dd” followed by the

two numbers of the month.

9.

Press and release the UP or DOWN key within 15 s to modify the value:

Operate as follows to set the hour:

10.

Press and release the BLAST CHILLING key when setting the day of the month: the display will show “hh

followed by the two numbers of the hour.

11.

Press and release the UP or DOWN key within 15 s to modify the value:

The hour is displayed in the 24 h format.

Operate as follows to set the minutes:

12.

Press and release the BLAST CHILLING key when setting the hour: the display will show “nn” followed by the

two numbers of the minutes.

13.

Press and release the UP or DOWN key within 15 s to modify the value:

14.

Press and release the BLAST CHILLING key or do not operate for 15 s: the display will show “rtc” again and the

LED will switch off.

Operate as follows to exit the procedure:

15.

Press and release the UP or DOWN key until the display shows the magnitude indicated in paragraph 5.3 "The

display" or do not operate for 60 s.

9.2

Setting the configuration parameters

Operate as follows:

1.

Make sure no procedures are in progress

2.

Hold the UP and DOWN key for 4 s: the display will show “PA”.

3.

Press and release the BLAST CHILLING key: the display will show “0

4.

Press and release the UP or DOWN key within 15 s to set “-19”.

5.

Press and release the BLAST CHILLING key or do not operate for 15 s: the display will show “PA” again.

6.

Hold the UP and DOWN key for 4 s: the display will show “SP”.

Operate as follows to set a parameter:

7.

Press and release the UP or DOWN key to select a parameter label.

8.

Press and release the BLAST CHILLING key: the display will show the value of the parameter.