EVCO EVXV815P7 Installer manual User Manual

Page 51

Advertising
background image

EVCO S.p.A.

EVXV 800 range | Installer manual ver. 1.2 | Code 144XV800E124

page 51 of 66

PF

Power cut alarm (HACCP alarm; in EVXV812 and EVXV815 models only).

Solutions:

-

check the device-power supply connection

-

check the value of the parameter A10.

Main consequences:

-

the device will memorise the alarm.

COH

Condenser overheated alarm.

Solutions:

-

check the temperature of the condenser

-

check the value of the parameter C6.

Main consequences:

-

the condenser fan will be switched on.

CSd

Compressor blocked alarm.

Solutions:

-

check the temperature of the condenser

-

check the value of the parameter C7

-

disconnect the device power supply and clean the condenser.

Main consequences:

-

if the error occurs during the “stand-by” status, no operating cycles can be selected or started

-

if the error occurs during an operating cycle, the cycle will be interrupted.

ESt

Configuration parameters download not completed successfully alarm.

Solutions:

-

press and release a key to restore normal display

-

download the configuration parameters again.

Main consequences:

-

the device will continue to operate normally.

CEr

Configuration parameters firmware contained in EVKEY not coinciding with that of the device.

Solutions:

-

cut the device power supply off

-

check that the configuration parameters firmware contained in EVKEY coincides with that of the

device

-

download the configuration parameters again.

Main consequences:

-

the device will continue to operate normally.

Erd

Configuration parameters upload not completed successfully alarm.

Solutions:

-

restore the factory settings

-

upload the configuration parameters again.

Main consequences:

-

the digital outputs will be switched off.