EVCO S.p.A.

EVXV 800 range | Installer manual ver. 1.2 | Code 144XV800E124

page 43 of 66

F17

-50.0

99.0

°C/°F (1)

90.0

90.0

cabinet

temperature

above

which

the

evaporator fan is off during pre-cooling, blast

chilling and deep freezing (only if parameter

F0 is set at 1 or 2); also see parameter F8

Par.

Min.

Max.

Unit

EVXV802

EVXV812

EVXV805

EVXV815

Digital inputs

i0

0

2

- - - -

2

2

effect caused by opening the door, i.e. by

activation of the door micro switch (14)

0 = no effect

1 = the compressor and the evaporator fan

will be off and the cabinet light will be

on. On expiry of the time established

with parameter i2, the display will

show the flashing “id” code and the

buzzer will be activated (until the door

is closed); also see parameter F15

(15)

2 = the evaporator fan will be off and the

cabinet light will be on. On expiry of

the time established with parameter

i2, the display will show the flashing

id” code and the buzzer will be

activated (until the door is closed);

also see parameter F15

i1

0

1

- - - -

0

0

type of door micro switch input contact

0 = normally open (input active with closed

contact)

1 = normally closed (input active with open

contact)

i2

-1

120

min

5

5

door open alarm signalling delay (“id” code) ;

on expiry of the time established with the

parameter, the compressor will be off

-1 = the alarm will not be signalled