User presses fingerprint

No

Record captured

User TZ

GRP TP

but can’t unlock door

Yes

No

Yes

No

TimeZone Deny

Effective TP

Yes

Voice prompts “Thank you”

No

User GRP in

to confirm success

unlocking Comb

Yes

Record

captured

and door opened

Satisfy certain

No

unlocking combination

Next GRP user

Yes

combine to unlock door

VERIFICATION FLOW OF ACCESS OPTIONS

If a user verifies his fingerprint and he is the user assigned in the time zone, the system will check
whether the user is included in the user group of unlocking combination. If yes, he has to satisfy
certain unlocking combination for the door to be unlocked. If he does not satisfy the unlocking
combination required, he will be denied access and he needs to be verified again.

If the user is in the time zone but not included in the effective time zone, he will be denied entry but
the data of his fingerprint will be recorded as data for time & attendance.