Note

This Chapter is meant for qualified installer only.

The installation of FingerTec® reader shall be han-

dled by a well-trained installer. If you are not a quali-

fied installer, you can ignore this Chapter or this

Chapter serves as reference for all types of connec-
tions available for the FingerTec® reader only.

FOR AC800 SERIES

The Communication I/O Controller

2 8 Pin Line Port

3 Mode Switch

4 Power Supply

1 Data I/O Port

5 Lock Control

6 Serial Port

7TCP/IP Port

5

INSTALLATION & COMMUNICATIONS

CONNECTIONS AVAILABLE

1

Data I/O Port:

The port is located at the back of the reader. This port is connected to the

8-Pin Line port at the Communication I/O Controller.

2

8-Pin Line Port:

Located at the back of the Communication I/O Controller. This port con-

nects to the back of the reader using the straight RJ45 cable provided. The distance from the
controller to the reader is recommended to be not more than 15 meters.

3

Mode Switch:

This switch switches between 2 different communication types. The switch on

the left is for RS232/RS485 connection and the switch on the right, is for TCP/IP connec-
tion.