FingerTec AC800 Plus MC User Manual

Page 51

Advertising
background image

52

Help Key

User may choose to enable the Help Key by
choosing “Yes”. The Help Key is to be used
when the ID of the duress finger is different
from the ID of the normal clocking activities.
Alarm will be triggered when user press the
down key button for 3 seconds followed by a
duress fingerprint on the scanner.

Trigger Methods

There are 3 types of trigger method by us-
ing duress finger which user can choose
from:

1:1 Trigger

To be used when user always use 1:N for

normal clocking activities.

1:N Trigger

To be used when user always use 1:1 for

normal clocking activities.

Password Trigger

To be used when user always use both

methods for normal clocking activities.
User may choose to select only one trig-
ger method. These trigger methods are
to be used if the ID for the duress finger
is the same as the ID of the clocking ac-
tivities.

Duress Delay

User can set the timer to trigger alarm after a
successful verification of a duress finger. The
timer can be set from 0 to 255 seconds and
the alarm will goes off when the time is up.

Access Control

FingerTec® reader can control any digital
lock or EM-lock that consumes 12V of power
and current of less than 1A.

Setup Lock Function

In Access menu, select “Options” > “Access
Options” > “Lock”. The value of lock setting is
the time period of a lock opens before it closes
again; one unit value is 20ms. The value is be-
tween 0-254 where “0” means no lock open-
ing signal is emitted and 254 is equivalent to
5s waiting time before the door closes.

Advertising
This manual is related to the following products: