FT-13 Technical Manual, Rev. 1.40 March 2013

Page 12 of 56

5. F

RONT

P

ANEL AND

K

EYPAD

5.1 Weight Display and Status LEDs

Figure 5.1 Front panel view of FT-13

The weight display of FT-13 is a 6 digit LED with 14 mm or 20 mm height. At the right side of the display there
are three status LEDs for indicating “Gross”, “Net” and the standard unit “kg”.

Below the weight display there are 6 status LEDs related to the weighing process. The meanings of these are:

Status LEDs related to the weighing process

LED

Meaning

Power: This LED will flash in case of supply voltage decrease. If the voltage decreases too much the
indicator will automatically shut off.

Key lock: is active

W Mod.

Weighing mode: is active

G/N

Gross/Net: LED is on when gross is displayed temporarely

Stable: The weight value on the display is stable

Center of zero: The weight is in the center of zero (see parameter [203] in chapter 6.5)


At the left side of the weight display there is a group of 6 status LEDs which give information about the current
filling process. The meaning depends on the selected filling programm (see chapter 7).

The digital I/Os have different meanings according to selected the filling programme (see chapter 4.2.3).

Status LEDs related to the filling process

LED

Meaning

READY

FT-13 is ready to start the filling process

START

LED is on if the start input is active

COARSE

Indicates coarse feeding process

FINE

Indicates fine feeding process

EOB

Indicates end of filling

DSCHRG

Indicates end of emptying / discharging (in Programme 3, 4, 5 and 6)