Ft-13 input – Flintec FT-13 User Manual

Page 50

Advertising
background image

FT-13 Technical Manual, Rev. 1.40 March 2013

Page 50 of 56

Any input to FT-13 is in four words and according to the table below.

FT-13 Input

Bit no.

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

1

st

Word

W31

MSB

W30

W29

W28

W27

W26

W25

W24

W23

W22

W21 W20 W19 W18 W17

W16

2

nd

Word

W15

W14

W13

W12

W11

W10

W9

W8

W7

W6

W5

W4

W3

W2

W1

W0

LSB

3

rd

Word

Pause

Hold

0

Dschrg Reset Start

Clear

Tare

Zero

New

Cmd

Command

CMD

R/W

4

th

Word

Not in use

Expanded Commands

Here the first and the second word describe the value received from the PLC, the third and the fourth word the
meaning as indicated below.

Bit no.

3

rd

Word

Description

15

Pause

A transition from 0 to 1 activates the Pause function in a filling process.
A transition from 1 to 0 deactivates the Pause function.

14

Hold

A transition from 0 to 1 activates the Hold function which stops the weight control in a filling
process and deactivates the feeding outputs.
A transition from 1 to 0 deactivates the Hold function.

13…12

Not used

Always 0

11

Reset

A transition from 0 to 1 activates the reset command.

10

Start

A transition from 0 to 1 activates the start command.

9

Clear

A transition from 0 to 1 activates the clear command.

8

Tare

A transition from 0 to 1 activates the tare command.

7

Zero

A transition from 0 to 1 activates the zero command.

6

New
command

A transition from 0 to 1 activates the command described in the table below.

5

Command

Command

R / W

Definition

00000

R

Gross Weight, continuous

00001

R

Displayed Weight, continuous

00010

R

Net Weight, continuous

00011

R

Tare Weight, continuous

00100

R / W

Filling / Weighing Mode
Write: Toggle operation mode between filling and weighing
Read: 0: weighing ; 1: filling (only 1

st

word)

00101

R / W

Target

00110

R / W

Tolerance

00111

R / W

Coarse

01000

R / W

Fine

01001

R / W

CN (only 1

st

word)

01010

R

Last filling value

01011

R / W

Quantity (only 1

st

word)

01100

R / W

Total

01101

R

Inputs (only 1

st

word), continuous

01110

R / W

Outputs, continuous

01111

R / W

Middle

10000

W

Zero calibration and calibration status (see table above)

10001

W

Calibrate span and and calibration status (see table above)
First write the calibration weight value in 1

st

and 2

nd

Word

10010

R

Only calibration status (see table above)

11111

Reserved

4

3

2

1

0

Command R /
W

0: Read command; 1: Write command

Bit no.

4

th

Word

Description

15…6

Not used

Always 0

5

Expanded
Commands

Cmd

R/W Definition

Prog. 0

Prog. 1

Prog. 2

Prog. 3

Prog. 4

Prog. 5

Prog. 6

00000

R/W D_FILL

D_FILL

D_FILL

D_DISC

D_MSG

D_MSG

D_DISC

00001

R/W TARE_

TARE_

D_VALF

D_GATE

ZERO_r GAT_CH

D_GATE

00010

R/W TARE=

TARE=

D_LIFT

E_TYPE

F_TRGT

E_TYPE

00011

R/W ZERO_r

SAFETY TARE_

GAT_CH

GAT_CH

00100

R/W GR-NET

ZERO_r

TARE=

ZERO_r

T_TRGT

00101

R/W

GR-NET

SAFETY

ZERO_r

00110

R/W

ZERO_r

00111

GR-NET

4

3

2

1

0